Chemical Protection

 

 

By placing a catalyst in the system’s hot air stream, chemical and environmental pollutants as well as organic particles and allergens are eliminated.  In a series of tests (see test data below), the BioBlower eliminated a broad range of chemical contaminants and particulate matter.

Compound

Reaction Products

Treatment Temp C

Reaction %

ammonia

N2, H2O

<160

>99

organic particles

CO2, H2O

<220

Qualitative test only

hexane

CO2, H2O

<190

>99

toluene

CO2, H2O

<190

>99

ethanol

CO2, H2O

<190

>99

acetone

CO2, H2O

<190

>99

Propylene oxide

CO2, H2O

<190

>99

 